Título: EFICIÊNCIA GLOBAL E CONSUMO ESPECÍFICO DE ENERGIA DA BOMBA CENTRÍFUGA KSB ETA 50-20
Título alternativo: GLOBAL EFFICIENCY AND SPECIFIC ENERGY USE OF A KSB ETA 50-20 PUMP
Autoria de: Otávio Prado Borges de Assis
Orientação de: Victor Buono da Silva Baptista
Presidente da banca: Victor Buono da Silva Baptista
Primeiro membro da banca: Thiago Henrique Burgarelli Teixeira
Segundo membro da banca: Paulo Henrique Brito Junior
Palavras-chaves: hidráulica, estação de bombeamento, modelagem hidráulica, curvas características, altura manométrica total
Data da defesa: 16/09/2022
Semestre letivo da defesa: 2022-1
Data da versão final: 21/09/2022
Data da publicação: 21/09/2022
Referência: Assis, O. P. B. d. EFICIÊNCIA GLOBAL E CONSUMO ESPECÍFICO DE ENERGIA DA BOMBA CENTRÍFUGA KSB ETA 50-20. 2022. 35 p. Trabalho de Conclusão de Curso (Graduação em Engenharia Ambiental e Sanitária Bacharelado)-Universidade Federal de Lavras, Lavras, 2022.
Resumo: O uso racional de energia para o transporte de água, tanto no meio urbano quanto no meio rural, é uma preocupação recorrente, ainda mais nos últimos anos devido as variações climáticas e ocorrências de secas nos reservatórios de água. Dessa forma, o objetivo deste trabalho foi analisar a variação do rendimento global e consumo específico de energia (CEE), através da comparação com dados experimentais de uma unidade de bombeamento antes e depois de passar uma manutenção corretiva. Para este estudo foi realizado o ensaio hidráulico e energético de uma unidade de bombeamento para obtenção das curvas características (vazão por altura manométrica (Q-HMT) e vazão por rendimento (Q-). A unidade de bombeamento é composta por (i) uma bomba KSB-ETA 5020 e rotação nominal de 3450 rpm (ii) um motor elétrico trifásico de 25cv, da marca WEG (iii) um inversor de frequência marca WEG, modelo CFW5. As determinações de rendimento foram repetidas sob valores de diferentes frequências (60, 55, 50, 45, 40, 30 Hz). Em cada fre
Abstract: The rational use of energy for water supply, both in urban and rural zones, is a recurring concern, even more so in recent years due to climatic variations and occurrences of droughts in water reservoirs. Thus, the objective of this work was to analyze the global efficiency and specific energy use (CEE) variation, through the comparison with experimental data of a pumping unit before and after undergoing corrective maintenance. For this study, the hydraulic and energy test of a pumping unit was carried out to obtain the characteristic curves (flow per head (Q-HMT) and flow per global efficiency (Q-). The pumping unit is composed (i) a KSB-ETA 5020 pump with nominal speed of 3450 rpm (ii) a 25cv three-phase electric motor, WEG brand (iii) a WEG brand frequency inverter, CFW5 model. Efficiency determinations were repeated under different frequency values (60, 55, 50, 45, 40, 30 Hz). At each frequency, for different pairs pumped flow and total dynamic head, the active electric power required to drive the var
URI: sip.prg.ufla.br/publico/trabalhos_conclusao_curso/acessar_tcc_por_curso/
engenharia_ambiental_e_sanitaria/20221201720560
URI alternaviva: sem URI do Repositório Institucional da UFLA até o momento.
Curso: G019 - ENGENHARIA AMBIENTAL E SANITÁRIA (BACHARELADO)
Nome da editora: Universidade Federal de Lavras
Sigla da editora: UFLA
País da editora: Brasil
Gênero textual: Trabalho de Conclusão de Curso
Nome da língua do conteúdo: Português
Código da língua do conteúdo: por
Licença de acesso: Acesso aberto
Nome da licença: Licença do Repositório Institucional da Universidade Federal de Lavras
URI da licença: repositorio.ufla.br
Termos da licença: Acesso aos termos da licença em repositorio.ufla.br
Detentores dos direitos autorais: Otávio Prado Borges de Assis e Universidade Federal de Lavras
Baixar arquivo